DC-DC Converters
Series HPD Single and Series HPD Dual
Isolated Regulated up to 200 Watts, Wide Input Range/200-380 VDC
Fully Regulated, Short Circuit Protected
Parallel Operation Available
Features:
Typical Characteristics:Frequency: 100 Khtz
For Parallel Operation: Add suffix "P" (i.e. HPD5SP). Consult factory to optimize for your application |
The PICO HPD Series of high power DC-DC Converters, allow a wide input voltage of 200-380 VDC, while maintaining a regulated output. They are fully safeguarded for over voltage, over temperature and continuous short circuit protection.
The availability of Dual Isolated Outputs, small size, and the capability of parallel operations as standard features should reduce your design and component costs, while the fixed frequency operation helps parallel connections for higher power requirements. This high density unit is assembled in the USA with PICO quality and component selection, allowing it to meet the most stringent commercial requirements.
|
Series HPD Single * 200 Watts * Input 200-380 VDC |
|||||||||||
Pico
Part No. |
Input
Voltage Range (V DC) |
Output
Voltage (V DC) |
Max.
Output Power * (W) |
EFF.
Full Load Typical ** (%) |
Max.
Load Regulation (%) *** |
Max.
Line Regulation At Full Load (%) |
Output
Voltage Ripple (Full Load) 1-1MHz BW (MV P-P) |
Output
Voltage Tolerance ** (± %) |
Price
(US $) |
||
10-50%
|
50-100%
|
200-300V
|
300-380V
|
||||||||
HPD3.3S
|
200-380
|
3.3
|
75
|
73
|
1.50
|
1.50
|
1.25
|
1.25
|
50
|
1.50
|
239.19
|
HPD5S
|
200-380
|
5
|
100
|
77
|
1.25
|
1.25
|
1.00
|
1.00
|
50
|
1.50
|
239.19
|
HPD5.2S
|
200-380
|
5.2
|
100
|
77
|
1.25
|
1.25
|
1.00
|
1.00
|
50
|
1.50
|
239.19
|
HPD9S
|
200-380
|
9
|
150
|
80
|
1.25
|
1.25
|
1.00
|
1.00
|
50
|
1.00
|
239.19
|
HPD12S
|
200-380
|
12
|
200
|
82
|
1.00
|
1.00
|
0.75
|
0.75
|
50
|
1.00
|
239.19
|
HPD15S
|
200-380
|
15
|
200
|
83
|
1.00
|
1.00
|
0.75
|
0.75
|
50
|
1.00
|
239.19
|
HPD24S
|
200-380
|
24
|
200
|
85
|
0.75
|
0.75
|
0.50
|
0.50
|
50
|
0.75
|
239.19
|
HPD28S
|
200-380
|
28
|
200
|
86
|
0.50
|
0.50
|
0.50
|
0.50
|
50
|
0.75
|
239.19
|
HPD48S
|
200-380
|
48
|
200
|
86
|
0.50
|
0.50
|
0.50
|
0.50
|
50
|
0.50
|
239.19
|
HPD100S
|
200-380
|
100
|
150
|
85
|
0.50
|
0.50
|
0.50
|
0.50
|
50
|
0.50
|
306.65
|
10% Minimum load required at all times. * Using proper thermal management, maximum temp. of +85º C (case) ** Reading taken at nominal 300 VDC input |
Series HPD Dual * 150 Watts * Input 200-380 VDC |
|||||||||||
Pico
Part No. |
Input
Voltage Range (V DC) |
Output
Voltage (V DC) |
Max.
Output Power * (W) |
EFF.
Full Load Typical ** (%) |
Max.
Load Regulation (%) *** |
Max.
Line Regulation At Full Load (%) |
Output
Voltage Ripple (Full Load) 1-1MHz BW (MV P-P) |
Output
Voltage Tolerance ** (± %) |
Price
(US $) |
||
10-50%
|
50-100%
|
200-300V
|
300-380V
|
||||||||
HPD5D
|
200-380
|
5
|
50/50
|
77
|
1.25
|
1.25
|
1.00
|
1.00
|
50
|
1.50
|
319.45
|
HPD9D
|
200-380
|
9
|
75/75
|
80
|
1.25
|
1.25
|
1.00
|
1.00
|
50
|
1.00
|
319.45
|
HPD12D
|
200-380
|
12
|
75/75
|
82
|
1.00
|
1.00
|
0.75
|
0.75
|
50
|
1.00
|
319.45
|
HPD15D
|
200-380
|
15
|
75/75
|
83
|
1.00
|
1.00
|
0.75
|
0.75
|
50
|
1.00
|
319.45
|
HPD24D
|
200-380
|
24
|
75/75
|
85
|
0.75
|
0.75
|
0.75
|
0.75
|
50
|
0.75
|
319.45
|
HPD28D
|
200-380
|
28
|
75/75
|
86
|
0.75
|
0.75
|
0.50
|
0.50
|
50
|
0.75
|
319.45
|
HPD48D
|
200-380
|
48
|
75/75
|
86
|
0.50
|
0.50
|
0.50
|
0.50
|
50
|
0.50
|
319.45
|
10% Minimum load required at all times. * Using proper thermal management, maximum temp. of +85º C (case) ** Reading taken at nominal 300 VDC input |
****HIGH VOLTAGE SERIES PDUP TO 350 VDC - 150 WATTS - INPUT 200-380 VDC |
|||||||||||
PICO
PART NO. |
INPUT
VOLTAGE RANGE (VDC) |
OUTPUT
VOLTAGE DC |
MAX.
OUTPUT POWER (W)* |
EFF. @
FULL LOAD TYPICAL (%)** |
MAX.
LOAD REGULATION (%)** |
MAX. LINE
REGULATION AT FULL LOAD (%) |
OUTPUT
VOLTAGE RIPPLE FULL LOAD 1-1MhZ BW (%) |
OUTPUT
VOLTAGE Tolerance (±%)** |
PRICE
(US $) |
||
20-50%
|
50-100%
|
200-300V
|
300-380V
|
||||||||
PD125S
|
200-380
|
125
|
150
|
85
|
0.5
|
0.5
|
0.3
|
0.3
|
1
|
0.5
|
214.99
|
PD150S
|
200-380
|
150
|
150
|
85
|
0.5
|
0.5
|
0.3
|
0.3
|
1
|
0.5
|
214.99
|
PD175S
|
200-380
|
175
|
150
|
85
|
0.5
|
0.5
|
0.3
|
0.3
|
1
|
0.5
|
214.99
|
PD200S
|
200-380
|
200
|
150
|
85
|
0.5
|
0.5
|
0.3
|
0.3
|
1
|
0.5
|
286.66
|
PD225S
|
200-380
|
225
|
125
|
85
|
0.5
|
0.5
|
0.3
|
0.3
|
1
|
0.5
|
286.66
|
PD250S
|
200-380
|
250
|
125
|
85
|
0.5
|
0.5
|
0.3
|
0.3
|
1
|
0.5
|
286.66
|
PD275S
|
200-380
|
275
|
100
|
85
|
0.5
|
0.5
|
0.3
|
0.3
|
1
|
0.5
|
286.66
|
PD300S
|
200-380
|
300
|
100
|
85
|
0.5
|
0.5
|
0.3
|
0.3
|
1
|
0.5
|
358.32
|
PD325S
|
200-380
|
325
|
100
|
85
|
0.5
|
0.5
|
0.3
|
0.3
|
1
|
0.5
|
358.32
|
PD350S
|
200-380
|
350
|
100
|
85
|
0.5
|
0.5
|
0.3
|
0.3
|
1
|
0.5
|
358.32
|
10% Minimum load required at all times *Using proper thermal management maximum temp of +85ºC (case) **Reading taken at nominal 300 VDC input ****UL approval pending |
For immediate engineering assistance or to place an order: Call Toll Free: 800-431-1064
PICO Electronics, Inc.
143 Sparks Ave. Pelham, NY 10803-1810
Tel: 914-738-1400 Fax: 914-738-8225