Military DC-DC Converters
Series LFB/LMB Single and Series LFB/LMB Dual
Isolated Regulated 75 Watts, Wide Input Range/36-72 VDC
Fully Regulated, Short Circuit Protected
Parallel Operation Available
Features:
For all variations, call factory. For Parallel Operation: Add suffix "P" Series LFB : (-40º C to +85º C Operating Temperature)
|
Typical Characteristics:Frequency: 100 Khtz
|
Surge: Meets MIL STD 704 | |
Vibration: Meets MIL STD 202 Method 204 Cond. D | |
Humidity: Meets MIL STD 202 Method 106 | |
Shock: Meets MIL STD 202 Method 213 Cond. I | |
Altitude: Meets MIL STD 202 Method 105 Cond. D | |
Selected MIL STD 883 Options also Available | |
Stabilization Bake: MIL STD 883 Method 1008 24 Hrs TA=125º C | |
Burn In: MIL STD 883 Method 1015 160 Hrs at 90º C, case | |
Temperature Cycle: MIL STD 883, -55ºC to +105ºC, Method 1010 Cond. B |
The PICO LFB and LMB Series of high power DC-DC Converters, allow a wide input voltage of 36-72 VDC, while maintaining a regulated output. They are fully safeguarded for over voltage, over temperature and continuous short circuit protection.
The availability of Dual Isolated outputs, small size, and the capability of parallel operation as standard features should reduce your design and component costs, while the fixed frequency operation helps parallel connections for higher power requirements.
This high density unit is assembled in the USA with PICO quality and component selection, allowing it to meet the most stringent commercial requirements.
Series LFB/LMB Single * 75 Watts * Input 36-72 VDC |
|||||||||||||
Input
Volt. Range (V DC) |
Output
Voltage (V DC) |
Max.
Output Power * (W) |
EFF.
Full Load Typical ** (%) |
Max.
Load Regulation (%)** |
Max.
Line Regulation At Full Load (%) |
Output
Voltage Ripple (Full Load) 1-1MHz BW (MV P-P) |
Output
Voltage Toler. ** (± %) |
Series LFB Single
(-40º C to +85º C) |
Series LMB Single
(-55º C to +85º C) |
||||
10 - 50%
|
50-100%
|
36-48V
|
48-72V
|
Pico
Part Number |
Price
(US $) |
Pico
Part Number |
Price
(US $) |
||||||
36-72
|
3.3
|
30
|
74
|
1.5
|
1.5
|
0.75
|
0.75
|
50
|
2.0
|
LFB3.3S
|
324.92
|
LMB3.3S
|
455.50
|
36-72
|
5
|
50
|
80
|
1.0
|
1.0
|
0.75
|
0.75
|
50
|
1.5
|
LFB5S
|
324.92
|
LMB5S
|
455.50
|
36-72
|
5.2
|
50
|
80
|
1.0
|
1.0
|
0.75
|
0.75
|
50
|
1.5
|
LFB5.2S
|
324.92
|
LMB5.2S
|
455.50
|
36-72
|
9
|
65
|
84
|
1.0
|
1.0
|
0.75
|
0.75
|
50
|
1.0
|
LFB9S
|
324.92
|
LMB9S
|
455.50
|
36-72
|
12
|
75
|
84
|
0.75
|
0.75
|
0.5
|
0.5
|
50
|
1.0
|
LFB12S
|
324.92
|
LMB12S
|
455.50
|
36-72
|
15
|
75
|
84
|
0.75
|
0.75
|
0.5
|
0.5
|
50
|
1.0
|
LFB15S
|
324.92
|
LMB15S
|
455.50
|
36-72
|
24
|
75
|
87
|
0.5
|
0.5
|
0.5
|
0.5
|
50
|
0.5
|
LFB24S
|
324.92
|
LMB24S
|
455.50
|
36-72
|
28
|
75
|
87
|
0.5
|
0.5
|
0.5
|
0.5
|
50
|
0.5
|
LFB28S
|
324.92
|
LMB28S
|
455.50
|
36-72
|
48
|
75
|
85
|
0.5
|
0.5
|
0.5
|
0.5
|
50
|
0.5
|
LFB48S
|
324.92
|
LMB48S
|
455.50
|
36-72
|
100
|
75
|
85
|
0.5
|
0.5
|
0.5
|
0.5
|
100
|
0.5
|
LFB100S
|
487.38
|
LMB100S
|
683.25
|
10% Minimum load required at all times. * Using proper thermal management, maximum temp. of +85º C (case) ** Reading taken at nominal 48 VDC input |
Series LFB/LMB Dual * 75 Watts * Input 36-72 VDC |
|||||||||||||
Input
Volt. Range (V DC) |
Output
Voltage (V DC) |
Max.
Output Power * (W) |
EFF.
Full Load Typical ** (%) |
Max.
Load Regulation (%)** |
Max.
Line Regulation At Full Load (%) |
Output
Voltage Ripple (Full Load) 1-1MHz BW (MV P-P) |
Output
Voltage Toler. ** (± %) |
Series LFB Dual
(-40º C to +85º C) |
Series LMB Dual
(-55º C to +85º C) |
||||
10-50%
|
50-100%
|
36-48V
|
48-72V
|
Pico
Part Number |
Price
(US $) |
Pico
Part Number |
Price
(US $) |
||||||
36-72
|
5
|
50
|
80
|
1
|
1
|
0.75
|
0.75
|
50
|
1.5
|
LFB5D
|
438.27
|
LMB5D
|
614.39
|
36-72
|
9
|
65
|
84
|
1
|
1
|
0.75
|
0.75
|
50
|
1
|
LFB9D
|
438.27
|
LMB9D
|
614.39
|
36-72
|
12
|
75
|
84
|
0.75
|
0.75
|
0.5
|
0.5
|
50
|
1
|
LFB12D
|
438.27
|
LMB12D
|
614.39
|
36-72
|
15
|
75
|
85
|
0.75
|
0.75
|
0.5
|
0.5
|
50
|
1
|
LFB15D
|
438.27
|
LMB15D
|
614.39
|
36-72
|
24
|
75
|
87
|
0.5
|
0.5
|
0.5
|
0.5
|
50
|
0.5
|
LFB24D
|
438.27
|
LMB24D
|
614.39
|
36-72
|
28
|
75
|
87
|
0.5
|
0.5
|
0.5
|
0.5
|
50
|
0.5
|
LFB28D
|
438.27
|
LMB28D
|
614.39
|
36-72
|
48
|
75
|
85
|
0.5
|
0.5
|
0.5
|
0.5
|
50
|
0.5
|
LFB48D
|
438.27
|
LMB48D
|
614.39
|
10% Minimum load required at all times. * Using proper thermal management, maximum temp. of +85º C (case) ** Reading taken at nominal 48 VDC input |
****HIGH VOLTAGE SERIES LFB/ LMBTO 250 VDC - 50 WATTS - INPUT 36-72 VDC |
|||||||||||||
INPUT |
OUTPUT |
MAX. |
EFF. @ |
REGULATION (%)** |
MAX. LINE
REGULATION AT FULL LOAD (%) |
OUTPUT
VOLTAGE RIPPLE FULL LOAD 1-1MHz BW (%) |
OUTPUT
VOLTAGE Tolerance (±%)** |
SERIES LFB SINGLE
-40ºC TO +85ºC |
SERIES LMB SINGLE
(-55ºC TO +85ºC) |
||||
20-50%
|
50-100%
|
36-48V
|
48-72V
|
PICO
PART NUMBER |
PRICE
(US $) |
PICO
PART NUMBER |
PRICE
(US $) |
||||||
36-72
|
125
|
50
|
84
|
0.5
|
0.5
|
0.3
|
0.3
|
1
|
0.5
|
LFB125S
|
487.38
|
LMB125S
|
683.25
|
36-72
|
150
|
50
|
84
|
0.5
|
0.5
|
0.3
|
0.3
|
1
|
0.5
|
LFB150S
|
487.38
|
LMB150S
|
683.25
|
36-72
|
175
|
50
|
84
|
0.5
|
0.5
|
0.3
|
0.3
|
1
|
0.5
|
LFB175S
|
487.38
|
LMB175S
|
683.25
|
36-72
|
200
|
50
|
84
|
0.5
|
0.5
|
0.3
|
0.3
|
1
|
0.5
|
LFB200S
|
649.85
|
LMB200S
|
911.00
|
36-72
|
225
|
50
|
84
|
0.5
|
0.5
|
0.3
|
0.3
|
1
|
0.5
|
LFB225S
|
649.85
|
LMB225S
|
911.00
|
36-72
|
250
|
50
|
84
|
0.5
|
0.5
|
0.3
|
0.3
|
1
|
0.5
|
LFB250S
|
649.85
|
LMB250S
|
911.00
|
10% Minimum load required at all times *Using proper thermal management, maximum temp of +85ºC (case) **Reading taken at nominal 48 VDC input ****UL approval recognition pending |
For immediate engineering assistance or to place an order: Call Toll Free: 800-431-1064
PICO Electronics, Inc.
143 Sparks Ave. Pelham, NY 10803-1810
Tel: 914-738-1400 Fax: 914-738-8225