PDF version

DC-DC Converters

Series LPD Single and Series LPD Dual

Isolated Regulated 75 Watts, Wide Input Range/200-380 VDC
Fully Regulated, Short Circuit Protected
Parallel Operation Available

 

Features:
  • Dual isolated outputs
  • Short circuit protection
  • Input voltage protection
  • Thermal, over temp. shutdown
  • Line regulation
  • Load regulation
  • No external components required
  • Hi density, hi efficiency design
  • Remote shutdown
  • Trim capabilities
  • Fixed frequency-100 Khtz
Typical Characteristics:

Frequency: 100 Khtz
Base plate: Max. +85º C
Operating temperature: See thermal chart, Min. 0º C ambient, Max. +85º C base plate temp.
Test conditions: 25º C ambient
Isolation Base Input: 2121 VDC
Isolation Input Output: 4242 VDC
Isolation Output to Base: 1000 VDC
Storage temperature: -55º C to +105º C

  • 23 Standard Models
    Hi Density 75 Watts
    Fixed Frequency
  • For all variations, call factory.

For Parallel Operation: Add suffix "P" (i.e. LPD5SP). Consult factory to optimize for your application.

The PICO LPD Series of high power DC-DC Converters, allow a wide input voltage of 200-380 VDC, while maintaining a regulated output. They are fully safeguarded for over voltage, over temperature and continuous short circuit protection.

The availability of Dual Isolated Outputs, small size, and the capability of parallel operations as standard features should reduce your design and component costs, while the fixed frequency operation helps parallel connections for higher power requirements.

This high density unit is assembled in the USA with PICO quality and component selection, allowing it to meet the most stringent commercial requirements.


Larger Version of Graph

 

 

Series LPD Single

75 Watts Input 200-380 VDC

Pico
Part
No.
Input
Voltage
Range
(V DC)
Output
Voltage
Per
Output
(V DC)
Max.
Output
Power
Per
Output
*
(W)
EFF.
Full Load
Typical
**
(%)
Max.
Load
Regulation
(%)
Max.
Line
Regulation
At Full Load
(%)
Output
Voltage
Ripple
(Full Load)
1-1MHz BW
(MV P-P)
Output
Voltage
Tolerance
**
(± %)
Price
(US $)
10-50%
50-100%
200-300 V
300-380 V
LPD3.3S
200-380
3.3
15
73
1.50
1.50
1.00
1.00
50
2.0
221.58
LPD5S
200-380
5
25
80
1.25
1.25
1.00
1.00
50
1.5
221.58
LPD5.2S
200-380
5.2
25
80
1.25
1.25
1.00
1.00
50
1.5
221.58
LPD9S
200-380
9
32.5
84
1.25
1.25
0.75
0.75
50
1.0
221.58
LPD12S
200-380
12
37.5
84
1.00
1.00
0.75
0.75
50
1.0
221.58
LPD15S
200-380
15
37.5
84
1.00
1.00
0.75
0.75
50
1.0
221.58
LPD24S
200-380
24
37.5
85
0.75
0.75
0.50
0.50
50
0.5
221.58
LPD28S
200-380
28
37.5
86
0.50
0.50
0.50
0.50
50
0.5
221.58
LPD48S
200-380
48
37.5
85
0.50
0.50
0.50
0.50
50
0.5
221.58
LPD100S
200-380
100
37.5
85
0.50
0.50
0.50
0.50
100
0.5
305.32
10% Minimum load required at all times.
* Using proper thermal management, maximum temp. of +85º C (case)
** Reading taken at nominal 300 VDC input

 

Series LPD Dual

75 Watts Input 200-380 VDC

Pico
Part
No.
Input
Voltage
Range
(V DC)
Output
Voltage
Per Output
(V DC)
Max.
Output
Power
per Output
*
(W)
EFF.
Full Load
Typical
**
(%)
Max.
Load
Regulation
(%)
Max.
Line
Regulation
At Full Load
(%)
Output
Voltage
Ripple
(Full Load)
1-1MHz BW
(MV P-P)
Output
Voltage
Tolerance
**
(± %)
Price
(US $)
10-50%
50-100%
200-300 V
300-380 V
LPD5D
200-380
5
25
80
1.25
1.25
1.0
1.0
50
1.5
298.87
LPD9D
200-380
9
32.5
84
1.25
1.25
0.75
0.75
50
1.0
298.87
LPD12D
200-380
12
37.5
84
1.0
1.0
0.75
0.75
50
1.0
298.87
LPD15D
200-380
15
37.5
84
1.0
1.0
0.5
0.5
50
1.0
298.87
LPD24D
200-380
24
37.5
85
0.75
0.75
0.5
0.5
50
0.5
298.87
LPD28D
200-380
28
37.5
86
0.5
0.5
0.5
0.5
50
0.5
298.87
LPD48D
200-380
48
37.5
85
0.5
0.5
0.5
0.5
50
0.5
321.22
10% Minimum load required at all times.
* Using proper thermal management, maximum temp. of +85º C (case)
** Reading taken at nominal 300 VDC input

 

***HIGH VOLTAGE SERIES LPD

TO 250 VDC - 50 WATTS - INPUT 200-380 VDC

PICO
PART
No.
INPUT
VOLTAGE
(VDC)
OUTPUT
VOLTAGE
DC
MAX.
OUTPUT
POWER
(W)*
EFF. @
FULL
LOAD
TYPICAL
(%)**
MAX.
LOAD
REGULATION
(%)**
MAX. LINE
REGULATION
AT FULL LOAD
(%)
OUTPUT
VOLTAGE
RIPPLE
FULL
LOAD
1-1 MHz
BW
(%)
OUTPUT
VOLTAGE
Tolerance
(±%)**
PRICE
(US $)
20-50%
50-100%
200-300V
300-380V
LPD125S
200-380
125
50
85
0.5
0.5
0.3
0.3
1.0
0.5
305.32
LPD150S
200-380
150
50
85
0.5
0.5
0.3
0.3
1.0
0.5
305.32
LPD175S
200-380
175
50
85
0.5
0.5
0.3
0.3
1.0
0.5
305.32
LPD200S
200-380
200
50
85
0.5
0.5
0.3
0.3
1.0
0.5
407.09
LPD225S
200-380
225
50
85
0.5
0.5
0.3
0.3
1.0
0.5
407.09
LPD250S
200-380
250
50
85
0.5
0.5
0.3
0.3
1.0
0.5
407.09
*Using proper themal management maximum temp of +85
ºC (case)
10% Minimum load required at all times.
** Reading taken at nominal 300 VDC input
*** UL approval pending

For immediate engineering assistance or to place an order:
Call Toll Free: 800-431-1064

PICO Electronics, Inc.

143 Sparks Ave. Pelham, NY 10803
Tel: 914-738-1400 Fax: 914-738-8225