Inner page banner


 

 

 

DC-DC Converters

Series LPB Single and Series LPB Dual

Isolated Regulated 75 Watts, Wide Input Range/36-72 VDC

Fully Regulated, Short Circuit Protected Parallel Operation Available

 

 

Features:
  • Dual isolated outputs
  • Short circuit protection
  • Input voltage protection
  • Thermal, over temp. shutdown
  • Line regulation
  • Load regulation
  • No external components required
  • Hi density, hi efficiency design
  • Remote shutdown
  • Trim capabilities
  • Fixed frequency-100 Khtz

 

Typical Characteristics:

Frequency: 100 Khtz
Base plate: Max. +85º C
Operating temperature: See thermal chart, Min. 0º C ambient, Max. +85º C base plate temp.
Test conditions: 25º C ambient
Isolation Base Input: 2121 VDC
Isolation Input Output: 4242 VDC
Isolation Output to Base: 1000 VDC
Storage temperature: -55º C to +105º C

  • 23 Standard Models
    Hi Density 75 Watts
    Fixed Frequency
  • For all variations, call factory.

For Parallel Operation: Add suffix "P" (i.e. LPB5SP). Consult factory to optimize for your application.

The PICO LPB Series of high power DC-DC Converters, allow a wide input voltage of 36-72 VDC, while maintaining a regulated output. They are fully safeguarded for over voltage, over temperature and continuous short circuit protection.

The availability of Dual Isolated Outputs, small size, and the capability of parallel operations as standard features should reduce your design and component costs, while the fixed frequency operation helps parallel connections for higher power requirements.

This high density unit is assembled in the USA with PICO quality and component selection, allowing it to meet the most stringent commercial requirements.

Larger Version of Graph

 

 

 

Series LPB Single * 75 Watts * Input 36-72 VDC

Pico
Part
No.

 

Input
Voltage
Range
(V DC)
Output
Voltage
(V DC)
Max.
Output
Power
*
(W)
EFF.
Full Load
Typical
**
(%)
Max.
Load
Regulation
(%)
Max.
Line
Regulation
At Full Load
(%)
Output
Voltage
Ripple
(Full Load)
1-1MHz BW
(MV P-P)
Output
Voltage
Tolerance
**
(± %)
Price
(US $)
10-50%
50-100%
36-48 V
48-72 V
LPB3.3S
36-72
3.3
30
74
1.5
1.5
0.75
0.75
50
2.0
221.58
LPB5S
36-72
5
50
80
1.0
1.0
0.75
0.75
50
1.5
221.58
LPB5.2S
36-72
5.2
50
80
1.0
1.0
0.75
0.75
50
1.5
221.58
LPB9S
36-72
9
65
84
1.0
1.0
0.75
0.75
50
1.0
221.58
LPB12S
36-72
12
75
84
0.75
0.75
0.5
0.5
50
1.0
221.58
LPB15S
36-72
15
75
84
0.75
0.75
0.5
0.5
50
1.0
221.58
LPB24S
36-72
24
75
87
0.5
0.5
0.5
0.5
50
0.5
221.58
LPB28S
36-72
28
75
87
0.5
0.5
0.5
0.5
50
0.5
221.58
LPB48S
36-72
48
75
85
0.5
0.5
0.5
0.5
50
0.5
221.58
LPB100S
36-72
100
75
85
0.5
0.5
0.5
0.5
100
0.5
305.32
10% Minimum load required at all times.
* Using proper thermal management, maximum temp. of +85º C (case)

** Reading taken at nominal 48 VDC input

 

Series LPB Dual * 75 Watts * Input 36-72 VDC

Pico
Part
No.

 

Input
Voltage
Range
(V DC)
Output
Voltage
(V DC)
Max.
Output
Power
*
(W)
EFF.
Full Load
Typical
**
(%)
Max.
Load
Regulation
(%)
Max.
Line
Regulation
At Full Load
(%)
Output
Voltage
Ripple
(Full Load)
1-1MHz BW
(MV P-P)
Output
Voltage
Tolerance
**
(± %)
Price
(US $)
10-50%
50-100%
36-48 V
48-72 V
LPB5D
36-72
5
50
80
1.0
1.0
0.75
0.75
50
1.5
298.87
LPB9D
36-72
9
65
84
1.0
1.0
0.75
0.75
50
1.0
298.87
LPB12D
36-72
12
75
84
0.75
0.75
0.5
0.5
50
1.0
298.87
LPB15D
36-72
15
75
85
0.75
0.75
0.5
0.5
50
1.0
298.87
LPB24D
36-72
24
75
87
0.5
0.5
0.5
0.5
50
0.5
298.87
LPB28D
36-72
28
75
87
0.5
0.5
0.5
0.5
50
0.5
298.87
LPB48D
36-72
48
75
85
0.5
0.5
0.5
0.5
50
0.5
321.22
10% Minimum load required at all times.
* Using proper thermal management, maximum temp. of +85º C (case)

** Reading taken at nominal 48 VDC input

 

***HIGH VOLTAGE SERIES LPB TO 250 VDC - 50 WATTS - INPUT 36-72 VDC

PICO
PART
NUMBER
INPUT
VOLTAGE
(VDC)
OUTPUT
VOLTAGE
DC
MAX.
OUTPUT
POWER
(W)*
EFF. @
FULL
LOAD
TYPICAL
(%)**
MAX.
LOAD
REGULATION
(%)**
MAX. LINE
REGULATION
AT FULL LOAD
(%)
OUTPUT
VOLTAGE
RIPPLE
FULL
LOAD
1-1 MHz
BW
(%)

OUTPUT
VOLTAGE
Tolerance
**
(±%)

PRICE
(US $)
20-50%
50-100%
36-48 V
48-72 V
LPB125S
36-72
125
50
84
0.5
0.5
0.3
0.3
1
0.5
305.22
LPB150S
36-72
150
50
84
0.5
0.5
0.3
0.3
1
0.5
305.22
LPB175S
36-72
175
50
84
0.5
0.5
0.3
0.3
1
0.5
305.32
LPB200S
36-72
200
50
84
0.5
0.5
0.3
0.3
1
0.5
407.99
LPB225S
36-72
225
50
84
0.5
0.5
0.3
0.3
1
0.5
407.99
LPB250S
36-72
250
50
84
0.5
0.5
0.3
0.3
1
0.5
407.09
*Using proper thermal management maximum temp. of +85ºC (case)
10% minimum load required at all times
** Readings taken at nominal 48 VDC input
*** UL approval pending

 

For immediate engineering assistance or to place an order:
Call Toll Free: 800-431-1064

PICO Electronics, Inc.

143 Sparks Ave. Pelham, NY 10803-1810
Tel: 914-738-1400 Fax: 914-738-8225