Inner page banner


 

 

DC-DC Converters

Series LPA Single and Series LPA Dual

Isolated Regulated 75 Watts, Wide Input Range/18-36 VDC
Fully Regulated, Short Circuit Protected
Parallel Operation Available

 

 

Features:

  • Dual isolated outputs
  • Short circuit protection
  • Input voltage protection
  • Thermal, over temp. shutdown
  • Line regulation
  • Load regulation
  • No external components required
  • Hi density, hi efficiency design
  • Remote shutdown
  • Trim capabilities
  • Fixed frequency-100 Khtz

Typical Characteristics:

Frequency: 100 Khtz
Base plate: Max. +85º C
Operating temperature: See thermal chart, Min. 0º C ambient, Max. +85º C base plate temp.
Test conditions: 25º C ambient
Isolation Base Input: 2121 VDC
Isolation Input Output: 4242 VDC
Isolation Output to Base: 1000 VDC
Storage temperature: -55º C to +105º C

  • 21 Standard Models
    Meets MIL STD 704 Surge Requirements
    Fixed Frequency
  • For all variations, call factory.

For Parallel Operation: Add suffix "P" (i.e. LPA5SP). Consult factory to optimize for your application.

The new PICO LPA Series of high power DC-DC Converters, allow a wide input voltage of 18-36 VDC, while maintaining a regulated output. They are fully safeguarded for over voltage, over temperature and continuous short circuit protection.

The availability of Dual Isolated Outputs, small size, and the capability of parallel operations as standard features should reduce your design and component costs, while the fixed frequency operation helps parallel connections for higher power requirements.

This high density unit is assembled in the USA with PICO quality and component selection, allowing it to meet the most stringent commercial requirements.

Larger Version of Graph

 

 

 

Series LPA Single * 75 Watts * Input 18-36 VDC

Pico
Part
No.
Input
Voltage
Range
(V DC)
Output
Voltage
(V DC)
Max.
Output
Power
*
(W)
EFF.
Full Load
Typical
**
(%)
Max.
Load
Regulation
(%)
Max.
Line
Regulation
At Full Load
(%)
Output
Voltage
Ripple
(Full Load)
1-1MHz BW
(MV P-P)
Output
Voltage
Tolerance
**
(± %)
Price
(US $)
10-50%
50-100%
18-28 V
28-36 V
LPA3.3S
18-36
3.3
30
73
1.5
1.5
1.0
1.0
50
2.0
221.58
LPA5S
18-36
5.0
50
80
1.25
1.25
1.0
1.0
50
1.5
221.58
LPA5.2S
18-36
5.2
50
80
1.25
1.25
1.0
1.0
50
1.5
221.58
LPA9S
18-36
9.0
60
84
1.25
1.25
1.0
1.0
50
1.0
221.58
LPA12S
18-36
12
60
85
1.25
1.25
1.0
1.0
50
0.75
221.58
LPA15S
18-36
15
65
85
1.0
1.0
0.75
0.75
50
0.75
221.58
LPA24S
18-36
24
75
87
0.75
0.75
0.5
0.5
50
0.75
221.58
LPA28S
18-36
28
75
87
0.5
0.5
0.5
0.5
50
0.5
221.58
LPA48S
18-36
48
75
85
0.5
0.5
0.5
0.5
50
0.5
221.58
LPA100S
18-36
100
75
85
0.5
0.5
0.5
0.5
100
0.5
305.32
10% Minimum load required at all times.
* Using proper thermal management, maximum temp. of +85º C (case)

** Reading taken at nominal 28 VDC input

 

Series LPA Dual * 75 Watts * Input 18-36 VDC

Pico
Part
No.
Input
Voltage
Range
(V DC)
Output
Voltage
(V DC)
Max.
Output
Power
*
(W)
EFF.
Full Load
Typical
**
(%)
Max.
Load
Regulation
(%)
Max.
Line
Regulation
At Full Load
(%)
Output
Voltage
Ripple
(Full Load)
1-1MHz BW
(MV P-P)
Output
Voltage
Tolerance
**
(± %)
Price
(US $)
10-50%
50-100%
18-28 V
28-36 V
LPA5D
18-36
5
50
80
1.25
1.25
1.0
1.0
50
1.5
298.87
LPA9D
18-36
9
60
84
1.25
1.25
1.0
1.0
50
1.0
298.87
LPA12D
18-36
12
60
85
1.25
1.25
1.0
1.0
50
0.75
298.87
LPA15D
18-36
15
65
85
1.0
1.0
0.75
0.75
50
0.75
298.87
LPA24D
18-36
24
75
87
0.75
0.75
0.5
0.5
50
0.5
298.87
LPA28D
18-36
28
75
87
0.5
0.5
0.5
0.5
50
0.5
298.87
LPA48D
18-36
48
75
85
0.5
0.5
0.5
0.5
50
0.5
321.22
10% Minimum load required at all times.
* Using proper thermal management, maximum temp. of +85º C (case)

** Reading taken at nominal 28 VDC input
 
 

*** HIGH VOLTAGE SERIES LPA

TO 200 VDC - 50 WATTS - INPUT 18-36 VDC

PICO PART NUMBER
INPUT VOLTAGE RANGE (VDC)
OUTPUT VOLTAGE (DC)
MAX. OUTPUT POWER (W)*
EFF. @ FULL LOAD TYPICAL (%)**
MAX. LOAD REGULATION (%)**
MAX. LINE REGULATION AT FULL LOAD (%)

OUTPUT VOLTAGE RIPPLE FULL LOAD 1-1 MHz BW
(%)

OUTPUT VOLTAGE Tolerance (±%)**
PRICE
(US $)
20-50%
50-100%
18-28 V
28-36 V
LPA125S
18-36
125
50
82
0.5
0.5
0.3
0.3
1
0.5
305.32
LPA150S
18-36
150
50
82
0.5
0.5
0.3
0.3
1
0.5
305.32
LPA175S
18-36
175
50
82
0.5
0.5
0.3
0.3
1
0.5
305.32
LPA200S
18-36
200
50
82
0.5
0.5
0.3
0.3
1
0.5
407.09
10% Minimum load required at all times

*Using proper thermal management maximum temp. Of +85ºC )case.
**Reading taken at nominal 28 VDC input
*** UL recognition pending

 

 

For immediate engineering assistance or to place an order:
Call Toll Free: 800-431-1064

PICO Electronics, Inc.

143 Sparks Ave. Pelham, NY 10803-1810
Tel: 914-738-1400 Fax: 914-738-8225