Inner page banner



Series HV
DC to DC Converters
Single and Dual Output

Hi Input Voltage (70-170 VDC)
Hi Reliability Industrial Grade
Isolated 1000VDC
Fully Regulated - up to 15 Watts
Short Circuit Protected

 

 

 

PICO's HV Series with wide input voltages are available in 32 different models. As switchers they accommodate a 70 to 170 VDC input, and offer both single and dual, regulated output. These isolated units will operate over a temperature range of -25º C to +70º C with no heat sink or electrical derating required. They are excellent for applications where a rectified output from a 110 VDC source is available.
 

 

FEATURES

  • Excellent line regulation ± 1.0% (70 VDC -170 VDC)
  • Excellent load regulation, from 25% to 100%, ± 2%
  • Continuous short circuit protection
  • Encapsulated semiconductors, conservatively rated for maximum reliability.
  • Isolation - 100 megohms at 1000 VDC
  • Wide input 70 VDC to 170 VDC

 

TYPICAL CHARACTERISTICS:

Test conditions: 25º C ambient
Input Voltage: 70-170 VDC
Converter frequency: 100 KHz to 1 MHz
Operating temperature: -20º C to +70º C ambient
Storage temperature: -55º to +105º C
Output voltage temperature coefficient: 0.02%/º C
Isolation: 1000 VDC

 

 

Series HVA - Single Output - 3 Watts
No Terminal Strip Available
Pico
Part
Number
Output
Voltage
(V DC)
Max.
Load
Current
(mA)
Max.
Output
Power
(watts)
EFF.@*
Full
Load
Typical
(%)
Output*
Voltage
Tolerance
(± %)
Load*
Regulation
25%-100%
Load
(± %)**
Line*
Regulation
@ Full
Load
(± %)
Output*
Voltage
Ripple
Typical
(mv p-p)
Price
(US $)
HVA3.3S
HVA5S
HVA5.2S
HVA12S
HVA15S
HVA24S
HVA28S
3.3
5
5.2
12
15
24
28
600
600
577
250
200
125
105
2
3
3
3
3
3
3
63
65
65
67
67
68
68
2
2
2
2
2
2
2
2
2
2
2
2
2
2
1
0.5
1
0.5
0.5
0.5
0.5
50
50
50
50
50
50
50
104.14
104.14
104.14
104.14
104.14
104.14
104.14
*Measurements taken at nominal input voltage.
**10% minimum load required.
Terminal strip not available HVA

 

Series HVB - Single Output - 5 Watts
THVB Terminal Strip Model***
* * *
Pico
Part
Number
Output
Voltage
(V DC)
Max.
Load
Current
(mA)
Max.
Output
Power
(watts)
EFF.@*
Full
Load
Typical
(%)
Output*
Voltage
Tolerance
(± %)
Load*
Regulation
25%-100%
Load
(± %)**
Line*
Regulation
@ Full
Load
(± %)
Output*
Voltage
Ripple
(mv p-p)
* * *
Price
(US $)
HVB3.3S
HVB5S
HVB5.2S
HVB12S
HVB15S
HVB24S
HVB28S
HVB48S
3.3
5
5.2
12
15
24
28
48
1000
1000
961
415
330
200
175
104
3.3
5
5
5
5
5
5
5
67
70
70
73
73
74
74
74
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
1
1
1
1
1
1
1
1
50
50
50
50
50
50
50
150
119.23
119.23
119.23
119.23
119.23
119.23
119.23
119.23
*Measurements taken at nominal input voltage.
**10% minimum load required.
***For terminal strip models begin Part Number with letter T. Add $15.00 to prices shown

 

Series HVC - Single Output - 10 Watts
THVC Terminal Strip Available***
* * *
Pico
Part
Number
Output
Voltage
(V DC)
Max.
Load
Current
(mA)
Max.
Output
Power
(watts)
EFF.@*
Full
Load
Typical
(%)
Output*
Voltage
Tolerance
(± %)
Load*
Regulation
25%-100%
Load
(± %)**
Line*
Regulation
@ Full
Load
(± %)
Output*
Voltage
Ripple
Typical
(mv p-p)
* * *
Price
(US $)
HVC3.3S
HVC5S
HVC5.2S
HVC12S
HVC15S
HVC24S
HVC28S
HVC48S
3.3
5
5.2
12
15
24
28
48
1515
1600
1538
830
660
415
355
208
5
8
8
10
10
10
10
10
67
69
69
75
77
77
77
74
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
1
1
1
1
1
1
1
1
50
50
50
50
50
50
50
200
134.32
134.32
134.32
134.32
134.32
134.32
134.32
134.32
*Measurements taken at nominal input voltage.
**10% minimum load required.
***For terminal strip models begin Part Number with letter T. Add $15.00 to prices shown

 

Series HVD - Single Output - 15 Watts
THVD Terminal Strip Model***
* * *
Pico
Part
Number
Output
Voltage
(V DC)
Max.
Load
Current
(mA)
Max.
Output
Power
(watts)
EFF.@*
Full
Load
Typical
(%)
Output*
Voltage
Tolerance
(± %)
Load*
Regulation
25%-100%
Load
(± %)**
Line*
Regulation
@ Full
Load
(± %)
Output*
Voltage
Ripple
Typical
(mv p-p)
* * *
Price
(US $)
HVD3.3S
HVD5S
HVD5.2S
HVD12S
HVD15S
HVD24S
HVD28S
HVD48S
3.3
5
5.2
12
15
24
28
48
1818
2000
1923
1250
1000
625
535
312
6
10
10
15
15
15
15
15
68
70
70
75
76
76
76
74
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
1
1
1
1
1
1
1
1
50
50
50
50
50
50
50
200
149.42
149.42
149.42
149.42
149.42
149.42
149.42
149.42
*Measurements taken at nominal input voltage.
**10% minimum load required.
***For terminal strip models begin Part Number with letter T. Add $15.00 to prices shown

 

 

 

Series HVA Single
Output / 3 Watts

Larger Size Drawing

 

Series HVB Single
Output / 5 Watts

Larger Size Drawing and Schematic

 

 

 

 

Series HVC Single
Output / 10 Watts

Larger Size Drawing and Schematic

 

 

 

Series HVD Single
Output / 15 Watts

Larger Size Drawing and Schematic

 

 

 

 

Series THVB Single
Output / 5 Watts

Measurements in inches

NOTE: The recommended torque for mounting screws is 3 to 5 In-Lbs

Larger Size Drawing and Schematic

 

 

 

 

Series THVC Single
Output / 10 Watts

Measurements in inches

NOTE: The recommended torque for mounting screws is 3 to 5 In-Lbs

Larger Size Drawing and Schematic

 

 

 

Series THVD Single
Output / 15 Watts

Measurements in inches

NOTE: The recommended torque for mounting screws is 3 to 5 In-Lbs

Larger Size Drawing and Schematic

 

 

 

Series HVA - Dual Output - 3 Watts
No Terminal Strip Available
Pico
Part
Number
Output
Voltage
(V DC)
Max.
Load
Current
Per Out.
(mA)
Max.
Output
Power
Per Out
(watts)
EFF.@*
Full
Load
Typical
(%)
Output*
Voltage
Tolerance
(± %)
Load*
Regulation
25%-100%
Load
(± %)**
Line*
Regulation
@ Full
Load
(± %)
Output*
Voltage
Ripple
Typical
(mv p-p)
PRICE
(US $)
HVA5D
HVA12D
HVA15D
± 5
± 12
± 15
300
125
100
1.5
1.5
1.5
63
65
67
2
2
2
2
2
2
1
1
1
50
25
25
123.76
123.76
123.76
*Measurements taken at nominal input voltage.
**10% minimum load required.
Terminal strip not available HVA

 

Series HVB - Dual Output - 5 Watts
THVB Terminal Strip Model ***
* * *
Pico
Part
Number
Output
Voltage
(V DC)
Max.
Load
Current
Per Out.
(mA)
Max.
Output
Power
Per Out
(watts)
EFF.@*
Full
Load
Typical
(%)
Output*
Voltage
Tolerance
(± %)*
Load*
Regulation
25%-100%
Load
(± %)**
Line*
Regulation
@ Full
Load
(± %)
Output*
Voltage
Ripple
Typical
(mv p-p)
* * *
PRICE
(US $)
HVB5D
HVB12D
HVB15D
± 5
± 12
± 15
500
200
165
2.5
2.5
2.5
70
73
73
2
2
2
2
2
2
1
1
1
50
25
25
138.85
138.85
138.85
*Measurements taken at nominal input voltage.
**10% minimum load required.
89.00***For terminal strip models begin Part Number with letter T. Add $15.00 to prices shown

 

 

Series HVC - Dual Output - 10 Watts
THVC Terminal Strip Model ***
* * *
Pico
Part
Number
Output
Voltage
(V DC)
Max.
Load
Current
Per Out.
(mA)
Max.
Output
Power
Per Out
(watts)
EFF.@*
Full
Load
Typical
(%)
Output*
Voltage
Tolerance
(± %)*
Load*
Regulation
25%-100%
Load
(± %)**
Line*
Regulation
@ Full
Load
(± %)
Output*
Voltage
Ripple
Typical
(mv p-p)
* * *
PRICE
(US $)
HVC5D
HVC12D
HVC15D
± 5
± 12
± 15
800
415
335
4
5
5
68
75
76
2
2
2
2
2
2
1
1
1
50
25
25
153.94
153.94
153.94
*Measurements taken at nominal input voltage.
**10% minimum load required.
***For terminal strip models begin Part Number with letter T. Add $15.00 to prices shown

 

 

Series HVD - Dual Output - 15 Watts
THVD Terminal Strip Model ***
* * *
Pico
Part
Number
Output
Voltage
(V DC)
Max.
Load
Current
Per Out.
(mA)
Max.
Output
Power
Per Out
(watts)
EFF.@*
Full
Load
Typical
(%)
Output*
Voltage
Tolerance
(± %)*
Load*
Regulation
25%-100%
Load
(± %)**
Line*
Regulation
@ Full
Load
(± %)
Output*
Voltage
Ripple
Typical
(mv p-p)
* * *
PRICE
(US $)
HVD5D
HVD12D
HVD15D
± 5
± 12
± 15
1000
625
500
5
7.5
7.5
69
75
76
2
2
2
2
2
2
1
1
1
50
25
25
169.04
169.04
169.04
*Measurements taken at nominal input voltage.
**10% minimum load required.
***For terminal strip models begin Part Number with letter T. Add $15.00 to prices shown

 

Series HVA Dual
Output / 3 Watts

Larger Size Drawing

 

Series HVB Dual
Output / 5 Watts

Larger Size Drawing and Schematic

 

 

 

 

Series HVC Dual
Output / 10 Watts

Larger Size Drawing and Schematic

 

 

 

Series HVD Dual
Output / 15 Watts

Larger Size Drawing and Schematic

 

 

 

 

 

 

Series THVB Dual
Output / 5 Watts

Measurements in inches

NOTE: The recommended torque for mounting screws is 3 to 5 In-Lbs

Larger Size Drawing and Schematic

 

 

 

 

Series THVC Dual
Output / 10 Watts

Measurements in inches

NOTE: The recommended torque for mounting screws is 3 to 5 In-Lbs

Larger Size Drawing and Schematic

 

 

 

Series THVD Dual
Output / 15 Watts

Measurements in inches

NOTE: The recommended torque for mounting screws is 3 to 5 In-Lbs

Larger Size Drawing and Schematic

 

 

 


For immediate engineering assistance or to place an order:
Call Toll Free: 800-431-1064

 

PICO Electronics, Inc.

143 Sparks Ave. Pelham, NY 10803-1810
Tel: 914-738-1400 or Fax: 914-738-8225

Go back to DC-DC Converters menu