AVR SERIES
Output Voltages -- 100Vdc up to 1000Vdc at 1 Watt
Miniature, Isolated, and Regulated
The Series AVR High Voltage DC-DC Converters is intended for users needing a miniature, isolated, regulated voltage source. These 1 Watt single output units offer high regulation along with low ripple and stability. AVR Units are protected against input Overvoltage, Output Overcurrent and Over Temperature. With no minimum load required, units can be safely operated from No Load to Full Load. Encapsulated in a miniature case and potted, units will operate over a temperature range of -25ºC to +70ºC with no heatsink or power derating.
These units are suitable for applications like electron beam deflection or focussing, photomultiplier tubes, piezo transducers or any other applications requiring regulated, isolated high-voltage sourc
FEATURES:
|
TYPICAL CHARACTERISTICS:
*NOTE*: Data measured at 25ºC ambient and Vin, nom, after warm-up unless otherwise specified. |
AVR SERIES1 Watt Single Output |
||||||||||
PICO
PART # |
INPUT
|
OUTPUT
|
REGULATION
|
EFFICIENCY
|
RIPPLE
Full Load Peak-Peak * (%) |
PRICE
(US $) |
||||
VOLTAGE
RANGE (V) |
CURRENT
* (mA) |
VOLTAGE
(V) |
MAX.
LOAD (mA) |
LINE
(%) |
LOAD |
LO LINE
(%) |
HI LINE
(%) |
|||
5AVR100
5AVR200 5AVR300 5AVR400 5AVR500 5AVR600 5AVR700 5AVR800 5AVR900 5AVR1000 |
4.5 - 5.5
4.5 - 5.5 4.5 - 5.5 4.5 - 5.5 4.5 - 5.5 4.5 - 5.5 4.5 - 5.5 4.5 - 5.5 4.5 - 5.5 4.5 - 5.5 |
410
410 410 410 410 410 410 410 410 410 |
100
200 300 400 500 600 700 800 900 1000 |
10
5.0 3.3 2.5 2.0 1.7 1.4 1.3 1.1 1.0 |
0.1
0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 |
0.25
0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 |
58
58 58 58 58 58 58 58 58 58 |
46
46 46 46 46 46 46 46 46 46 |
0.25
0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 |
177.63
177.63 177.63 177.63 198.46 198.46 198.46 226.63 226.63 226.63 |
12AVR100
12AVR200 12AVR300 12AVR400 12AVR500 12AVR600 12AVR700 12AVR800 12AVR900 12AVR1000 |
10.5 - 13.5
10.5 - 13.5 10.5 - 13.5 10.5 - 13.5 10.5 - 13.5 10.5 - 13.5 10.5 - 13.5 10.5 - 13.5 10.5 - 13.5 10.5 - 13.5 |
165
165 165 165 165 165 165 165 165 165 |
100
200 300 400 500 600 700 800 900 1000 |
10
5.0 3.3 2.5 2.0 1.7 1.4 1.3 1.1 1.0 |
0.1
0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 |
0.25
0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 |
63
63 63 63 63 63 63 63 63 63 |
49
49 49 49 49 49 49 49 49 49 |
0.25
0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 |
177.63
177.63 177.63 177.63 198.46 198.46 198.46 226.63 226.63 226.63 |
24AVR100
24AVR200 24AVR300 24AVR400 24AVR500 24AVR600 24AVR700 24AVR800 24AVR900 24AVR1000 |
21 - 27
21 - 27 21 - 27 21 - 27 21 - 27 21 - 27 21 - 27 21 - 27 21 - 27 21 - 27 |
80
80 80 80 80 80 80 80 80 80 |
100
200 300 400 500 600 700 800 900 1000 |
10
5.0 3.3 2.5 2.0 1.7 1.4 1.3 1.1 1.0 |
0.1
0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 |
0.25
0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 |
65
65 65 65 65 65 65 65 65 65 |
50
50 50 50 50 50 50 50 50 50 |
0.25
0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 |
177.63
177.63 177.63 177.63 198.46 198.46 198.46 226.63 226.63 226.63 |
28AVR100
28AVR200 28AVR300 28AVR400 28AVR500 28AVR600 28AVR700 28AVR800 28AVR900 28AVR1000 |
25 - 32
25 - 32 25 - 32 25 - 32 25 - 32 25 - 32 25 - 32 25 - 32 25 - 32 25 - 32 |
65
65 65 65 65 65 65 65 65 65 |
100
200 300 400 500 600 700 800 900 1000 |
10
5.0 3.3 2.5 2.0 1.7 1.4 1.3 1.1 1.0 |
0.1
0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 |
0.25
0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 |
65
65 65 65 65 65 65 65 65 65 |
50
50 50 50 50 50 50 50 50 50 |
0.25
0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 |
177.63
177.63 177.63 177.63 198.46 198.46 198.46 226.63 226.63 226.63 |
All specifications are given under the following conditions: +25ºC ambient and full load Measurements taken after warm up * At nominal input voltages |
SERIES AVR |
|||||||||||||
|
|
TO SHUT DOWN THE UNIT, THE VOLTAGE BETWEEN PINS 2 AND 3 MUST BE 0.28 VDC OR LESS. THE UNIT WILL AUTOMATICALLY RESTARY WHEN THE CIRCUIT BETWEEN PINS 2 AND 3 IS OPEN. PLEASE REVIEW THE TYPICAL EXAMPLES OF SHUT DOWN CIRCUITS BELOW. |
TYPICAL START UP RESPONSE Channel 1: 200 Volt/division; 10 ms/division Unit Tested: 5AVR1000 (5 Vin, 1000 Vout) operated at full load. |
TYPICAL TRANSIENT RESPONSE Load Change: 100% to 0% full load Unit Tested: 5AVR1000 (5 Vin, 1000 Vout). |
For immediate engineering assistance or to place an order: Call Toll Free: 800-431-1064 PICO Electronics, Inc.143 Sparks Ave., Pelham, N.Y. 10803-1810 |