88265

Series 87000, 88000, & 89000 – Power Transformer

Specifications

MountingThrough Hole
Operating Frequency (±20 Hz)400
Input Voltage (Vrms)26
Output Voltage -- Series Connection (Vrms)48
Output Current -- Series Connection (mA)521
Maximum Power (VA)25
Typical Regulation (%)8
Dielectric Withstanding Voltage (Vrms)200
Insulation Resistance (300 to 500 VDC)≥ 10 GΩ
Operational Temperature (°C)-55 to +130
Typical Weight (g)100
Size (L x W x H) inches1.63" x 1.63" x 0.83"
Moisture Sensitivity Level3
CaseGlass Reinforced Polymer
ConstructionEncapsulated
Manufactured toMIL-PRF-27

Description

400Hz power transformers are used in various energy conversion power supplies. They are crucial to aerospace and military industry for aircraft systems as the lightweight solution to the traditional 50/60Hz heavy electronics. The application is not limited to flight systems, but also in stationary controls, airport equipment, and vehicle mobility systems. This larger class of 400Hz power transformers has an operating temperature range from -55°C to +130°C.