38200
Series 38000 – Current Sense Transformer
Specifications
MountingThrough Hole
Current (A)15
Turns Ratio1:30
Secondary Inductance Min. (mH)1.62
Secondary DCR (Ohms)0.027
Frequency Range (kHz)50 to 500
Dielectric Withstanding Voltage (Vrms)500
Insulation Resistance at 500VDC≥ 10 GΩ
Operational Temperature (°C)-55ºC to +130ºC
Max. Weight (g)4
Size (L x W x H) inches0.55" x 0.55" x 0.25"
CaseGlass Reinforced Polymer
ConstructionEncapsulated
Manufactured toMIL-PRF-27
Description
Pico current sense transformers are designed for load management for power circuit protection. They provide the safest step-up current monitoring by allowing measurement of the current on the low side. This ensures proper load profiling in energy industry for system distribution and effective in cost allocation by metering the data output. At the same time, these devices maintain electrical isolation in power supplies and uphold minimal sensitivity to temperature change. The current rating extends from 5A to 20A.