Military DC-DC Converters
Series FD/MD Single and Series FD/MD Dual
Isolated Regulated 100 Watts, Wide Input Range/200-380 VDC
Fully Regulated, Short Circuit Protected
Parallel Operation Available
Features:
|
Typical Characteristics:Frequency: 100 Khtz
For all variations, call factory. For Parallel Operation: Add suffix "P", (i.e. FD/MD5SP) |
Series FD : (-40º C to +85º C Operating Temperature) Series MD : (-55º C to +85º C Operating Temperature) |
|
Surge | Meets MIL STD 704 |
Vibration | Meets MIL STD 202 Method 204 Cond. D |
Humidity | Meets MIL STD 202 Method 106 |
Shock | Meets MIL STD 202 Method 213 Cond. I |
Altitude | Meets MIL STD 202 Method 105 Cond. D |
Selected MIL STD 883 Options also Available | |
Stabilization Bake | MIL STD 883 Method 1008 24 Hrs TA=125º C |
Burn In | MIL STD 883 Method 1015 160 Hrs at 90º C |
Temperature Cycle | MIL STD 883, -55ºC to +105ºC, Method 1010 Cond. B |
The PICO FD and MD Series of high power DC-DC Converters, allow a wide input voltage of 200-380 VDC, while maintaining a regulated output. They are fully safeguarded for over voltage, over temperature and continuous short circuit protection.
The availability of Dual Isolated outputs, small size, and the capability of parallel operation as standard features should reduce your design and component costs, while the fixed frequency operation helps parallel connections for higher power requirements.
This high density unit is assembled in the USA with PICO quality and component selection, allowing it to meet the most stringent commercial requirements.
Series FD/MD Single * 100 Watts * Input 200-380 VDC
|
|||||||||||||
Input
Volt. Range (V DC) |
Outp.
Volt. (V DC) |
Max.
Output Power * (W) |
EFF.
Full Load Typical ** (%) |
Max.
Load Regulation (%)** |
Max.
Line Regulation At Full Load (%) |
Output
Voltage Ripple (Full Load) 1-1MHz BW (MV P-P) |
Outp.
Volt. Toler. ** (± %) |
Series FD Single
(-40º C to +85º C) |
Series MD Single
(-55º C to +85º C) |
||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
10-50%
|
50-100%
|
200-300V
|
300-380V
|
Pico Part Number |
Price
(US $) |
Pico
Part Number |
Price
(US $) |
||||||
200-380
|
3.3
|
50
|
76
|
1.50
|
1.50
|
1.25
|
1.25
|
50
|
2.0
|
FD3.3S
|
261.95
|
MD3.3S
|
367.22
|
200-380
|
5
|
75
|
78
|
1.25
|
1.25
|
1.00
|
1.00
|
50
|
1.5
|
FD5S
|
261.95
|
MD5S
|
367.22
|
200-380
|
5.2
|
75
|
78
|
1.25
|
1.25
|
1.00
|
1.00
|
50
|
1.5
|
FD5.2S
|
261.95
|
MD5.2S
|
367.22
|
200-380
|
9
|
100
|
84
|
1.25
|
1.25
|
1.00
|
1.00
|
50
|
1.0
|
FD9S
|
261.95
|
MD9S
|
367.22
|
200-380
|
12
|
100
|
85
|
1.00
|
1.00
|
0.75
|
0.75
|
50
|
1.0
|
FD12S
|
261.95
|
MD12S
|
367.22
|
200-380
|
15
|
100
|
86
|
1.00
|
1.00
|
0.75
|
0.75
|
50
|
1.0
|
FD15S
|
261.95
|
MD15S
|
367.22
|
200-380
|
24
|
100
|
87
|
0.75
|
0.75
|
0.50
|
0.50
|
50
|
0.5
|
FD24S
|
261.95
|
MD24S
|
367.22
|
200-380
|
28
|
100
|
87
|
0.50
|
0.50
|
0.50
|
0.50
|
50
|
0.5
|
FD28S
|
261.95
|
MD28S
|
367.22
|
200-380
|
48
|
100
|
88
|
0.50
|
0.50
|
0.20
|
0.20
|
50
|
0.5
|
FD48S
|
261.95
|
MD48S
|
367.22
|
200-380
|
100
|
100
|
88
|
0.50
|
0.50
|
0.20
|
0.20
|
50
|
0.5
|
FD100S
|
392.93
|
MD100S
|
550.84
|
10% Minimum load required at all times. * Using proper thermal management, maximum temp. of +85º C (case) ** Reading taken at nominal 300 VDC input |
Series FD/MD Dual * 100 Watts * Input 200-380 VDC
|
|||||||||||||
Input
Volt. Range (V DC) |
Outp.
Volt. (V DC) |
Max.
Output Power * (W) |
EFF.
Full Load Typical ** (%) |
Max.
Load Regulation (%)** |
Max.
Line Regulation At Full Load (%) |
Output
Voltage Ripple (Full Load) 1-1MHz BW (MV P-P) |
Outp.
Volt. Toler. ** (± %) |
Series FD Dual
(-40º C to +85º C) |
Series MD Dual
(-55º C to +85º C) |
||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
10-50%
|
50-100%
|
200-300V
|
300-380V
|
Pico
Part Number |
Price
(US $) |
Pico
Part Number |
Price
(US $) |
||||||
200-380
|
5
|
37.5/37.5
|
78
|
1.25
|
1.25
|
1.00
|
1.00
|
50
|
1.5
|
FD5D
|
375.30
|
MD5D
|
526.12
|
200-380
|
9
|
50/50
|
84
|
1.25
|
1.25
|
1.00
|
1.00
|
50
|
1.0
|
FD9D
|
375.30
|
MD9D
|
526.12
|
200-380
|
12
|
50/50
|
85
|
1.00
|
1.00
|
0.75
|
0.75
|
50
|
1.0
|
FD12D
|
375.30
|
MD12D
|
526.12
|
200-380
|
15
|
50/50
|
86
|
1.00
|
1.00
|
0.75
|
0.75
|
50
|
1.0
|
FD15D
|
375.30
|
MD15D
|
526.12
|
200-380
|
24
|
50/50
|
87
|
0.75
|
0.75
|
0.50
|
0.50
|
50
|
0.5
|
FD24D
|
375.30
|
MD24D
|
526.12
|
200-380
|
28
|
50/50
|
87
|
0.50
|
0.50
|
0.50
|
0.50
|
50
|
0.5
|
FD28D
|
375.30
|
MD28D
|
526.12
|
200-380
|
48
|
50/50
|
88
|
0.50
|
0.50
|
0.50
|
0.50
|
50
|
0.5
|
FD48D
|
375.30
|
MD48D
|
526.12
|
10% Minimum load required at all times. * Using proper thermal management, maximum temp. of +85º C (case) ** Reading taken at nominal 300 VDC input |
****HIGH VOLTAGE SERIES FD/MD
|
|||||||||||||
VOLTAGE RANGE (VDC) |
VOLTAGE (VDC) |
OUTPUT POWER (W)* |
FULL LOAD TYPICAL (%)** |
LOAD REGULATION (%)** |
LINE REGULATION AT FULL LOAD (%) |
VOLTAGE RIPPLE FULL LOAD 1-1MHz BW (%) |
VOLTAGE Tolerance (±%)* |
(-40ºC to +85ºC) |
(-55º to +85ºC) |
||||
|
|
|
|
PART NUMBER |
(US $) |
PART NUMBER |
(US $) |
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
637.02
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
10% Minimum load required at all times *Using proper thermal management maximum temp of +85º C (case) **Reading taken at nominal 300 VDC input ****UL approval recognition pending |
For immediate engineering assistance or to place an order: Call Toll Free: 800-431-1064
PICO Electronics, Inc.
143 Sparks Ave. Pelham, NY 10803-1810
Tel: 914-738-1400 Fax: 914-738-8225